Human Lymph Node

10x Genomics obtained fresh frozen human lymph node from BioIVT Asterand. The tissue was embedded and cryosectioned as described in Visium Spatial Protocols - Tissue Preparation Guide Demonstrated Protocol (CG000240). Tissue sections of 10 µm thickness were placed on Visium Gene Expression Slides.

The H&E image was acquired using a Nikon Ti2-E microscope with the following settings:

  • Color camera
  • 10X objective
  • Numerical Aperture: 0.45
  • Exposure: 2 ms
  • Gain: 4.5X

The Visium Spatial Gene Expression library was prepared following the Visium Spatial Gene Expression Reagent Kits User Guide (CG000239).

  • Sequencing instrument: Illumina NovaSeq 6000
  • Sequencing Depth: 123,189 reads per spot
  • Sequencing Configuration: 28 x 120 bp
  • Sequencing Coverage: Read 1 - 16 bp (includes 16 bp Spatial Barcode, 12 bp UMI); Read 2 - 120 bp (transcript); i7 sample index - 10 bp; i5 sample index - 10 bp.
  • Dual-Index set: T1T2-E3
  • Slide: V19L01-033
  • Area: A1

Key cell metrics were:

  • Spots detected under tissue - 4,039
  • Median UMI counts per spot - 16,853
  • Median genes per spot - 5,347

To maintain donor anonymity, sequence data for this sample is not currently available.

About this dataset

This Spatial Gene Expression dataset provides spatially resolved gene expression measured across a tissue section from human lymph node samples. 10x Genomics published it on December 12, 2019. The data were processed with Space Ranger 1.0.0, and the 10 output files total 884.5 MB.

This page is the Space Ranger 1.0.0 release of the sample. Another release of the same sample is listed under Related datasets; choose the newer pipeline unless you need to reproduce older results.

Analyze it in Drylab

Open this dataset in Drylab and ask a question in plain language. The AI agent loads the files, runs the analysis in a ready sandbox and explains each result. A typical first pass:

  1. Load the filtered feature-barcode matrix together with the tissue image and spot positions.
  2. Check tissue coverage and remove low-quality spots, then normalize counts.
  3. Cluster spots and map the clusters back onto the H&E image to see tissue domains.
  4. Find spatially variable genes and deconvolve spots into likely cell types with a single-cell reference.
  5. Open the Loupe file to browse the results interactively alongside Drylab.

Files to start with

  • Feature / barcode matrix HDF5 (filtered) (26.1 MB)
  • Spatial imaging data (8.3 MB)
  • Summary CSV (953 B)
  • Summary HTML (8.3 MB)
  • Loupe Browser file (281.3 MB)